Radiographic evaluation of marginal bone levels around implants supporting splinted fixed bridges: A retrospective study on 412 implants.

Mattia ManfrediniPier Paolo PoliMario BerettaFederico RossiMarta RigoniValentina VeronesiCarlo Maiorana
Published in: Clinical oral implants research (2024)
In case of ≥3 adjacent implants supporting splinted bridges, central implants were more predisposed to MBL compared to laterals. At the prosthesis level, implants supporting cement-retained bridges were statistically more susceptible to MBL compared to screw-retained ones. Surface characteristics can also influence MBL stability at the implant level.
Keyphrases
  • soft tissue