HPLC-FLD determination of aflatoxins M 1 and M 2 in raw cow milk samples using in-syringe gas-controlled density tunable solidification of a floating organic droplet-based dispersive liquid-liquid microextraction method.
Maede RabieMohammadhosein MovassaghghazaniMohammad Reza Afshar MogaddamPublished in: RSC advances (2024)
Herein, an in-syringe gas-controlled density tunable solidification of a floating organic droplet-based dispersive liquid-liquid microextraction method was employed for the extraction of aflatoxin M 1 and M 2 from cow milk samples prior to their quantification with high-performance liquid chromatography equipped with a fluorescence detector. In this method, after precipitating the proteins of the sample using a zinc sulfate solution, the supernatant phase was transferred into a barrel of a glass syringe, with the end closed with a septum containing a mixture of menthol, phenylacetic acid DES (as the extraction solvent), and chloroform (as a density modifier). After that, an inert gas was bubbled into the syringe. In this manner, chloroform was evaporated and fine droplets of extractant were released, which extracted the analytes during their passing. Finally, the syringe was placed in an ice bath and the obtained solidified drop was injected into the separation system after diluting with a mobile phase. Under the best analysis conditions, low limits of detection (1.45 and 1.86 ng L -1 for AFM 1 and AFM 2 , respectively) and quantification (4.83 and 6.21 ng L -1 for AFM 1 and AFM 2 , respectively), high extraction recovery (75 and 70% for AFM 1 and AFM 2 , respectively), and good precision (relative standard deviations ≤ 4.8%) were obtained by employing the approach reported in this study. In the end, this method was successfully employed to determine AFM 1 and AFM 2 in raw cow milk samples collected from Tabriz, Iran.
Keyphrases
- solid phase extraction
- high performance liquid chromatography
- atomic force microscopy
- high speed
- simultaneous determination
- molecularly imprinted
- ionic liquid
- liquid chromatography tandem mass spectrometry
- tandem mass spectrometry
- liquid chromatography
- mass spectrometry
- gas chromatography
- single molecule
- gas chromatography mass spectrometry
- room temperature
- magnetic resonance imaging
- high throughput
- computed tomography
- air pollution
- ms ms
- energy transfer
- water soluble
- label free
- image quality
- municipal solid waste