GUide sheath Advancement and aspiRation in the Distal petrocavernous internal carotid artery (GUARD) Technique during Thrombectomy Improves Reperfusion and Clinical Outcomes.
Sameer A AnsariM DarwishRamez N AbdallaDonald R CantrellAli ShaibaniMichael C HurleyBabak S JahromiMatthew B PottsPublished in: AJNR. American journal of neuroradiology (2019)
The GUARD technique during mechanical thrombectomy with combined stent retrieval-distal access catheter aspiration is safe and effective in improving reperfusion and clinical outcomes.