Left femoral vein access for transcatheter mitral valve interventions in unfavorable interatrial septal anatomy.

Francesco MaisanoGiulio RussoAna Paula TagliariMara GavazzoniMaurizio Taramasso
Published in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2021)
Optimal transseptal puncture (TSP) position on the interatrial septum as well as proper catheter direction and maneuverability in the left atrium (LA) are key elements for successful mitral valve (MV) interventions. TSP is usually performed from the right femoral vein being more comfortable for the operator and easier to reach the fossa ovalis. In the cases reported, TSP was performed from left femoral vein (LFV) to improve delivery system maneuverability and trajectory inside the LA in the context of MV repair with MitraClip. According to this early experience, LFV approach might be considered as first choice or as an alternative solution in patients in whom a higher position of the delivery system relative to the mitral annulus is needed.