Two-year outcomes of Xen 45 gel stent implantation in patients with open-angle glaucoma: real-world data from the Fight Glaucoma Blindness registry.
Louis ArnouldElise BalsatYohei HashimotoAndrew WhiteGeorge KongHamish DunnLeo FanPierre Henri GabrielleAlain-Marie BronCatherine P Creuzot-GarcherMitchell LawlorPublished in: The British journal of ophthalmology (2024)
The Xen 45 gel stent implant offers acceptable long-term efficacy for the treatment of open-angle glaucoma. However, there is a significant rate of reoperation and needling, and outcomes are less effective if combined with cataract surgery.