Auto- versus human-driven plan in mediastinal Hodgkin lymphoma radiation treatment.
Stefania ClementeCaterina OlivieroGiuseppe PalmaVittoria D'AvinoRaffaele LiuzziManuel ConsonRoberto PacelliLaura CellaPublished in: Radiation oncology (London, England) (2018)
Despite the high interpatient PTV (size and position) variability, it was possible to set a standard SHL AP optimization list with a high level of generalizability. Using the implemented list, the AP module was able to limit OAR doses, producing clinically acceptable plans with stable quality without additional user input. Overall, the AP engine associated to the arc technique represents the best option for SHL.