Quantification of visceral perfusion and impact of femoral cannulation: in vitro model of aortic dissection.

Woon HeoGyu-Han LeeTae-Hoon KimYoungjin LeeHyungkyu HuhHojin HaSuk-Won SongKyung-Jong Yoo
Published in: European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery (2022)
Our model was useful to understanding the haemodynamics in aortic dissection. In this specific condition, we confirmed that the intimal flap motion can partially block blood flow to the coeliac and superior mesenteric arteries and that additional femoral cannulation can increase visceral perfusion.