Rapid on-site evaluation in percutaneous core needle biopsies of renal masses: Cytologic-histologic concordance and diagnostic challenges.
Seyed Amin HojatNakul A RavishGissou AzabdaftariZhongbo YangPublished in: Diagnostic cytopathology (2023)
Our study showed a relatively high-concordance rate of 84.6% between ROSE interpretations and CNB final diagnoses, suggesting that ROSE is a valuable tool for procurement of adequate renal CNB samples for diagnosis.