[Optimization of phacoemulsification technique for Morgagnian cataract].
E S PirogovaO L FabrikantovS I NikolashinPublished in: Vestnik oftalmologii (2024)
The anatomical and topographic features of the lens and the anterior segment of the eye in Morgagnian cataract with a small nucleus allow for preliminary implantation of an intraocular lens into the capsular bag to protect the posterior capsule during phacoemulsification of the nucleus with minimal mechanical, hydrodynamic and acoustic damage to the surrounding structures of the eye.