Login / Signup

The Effectiveness and Safety of Intrathecal Fluorescein in the Management of Cerebrospinal Fluid Leaks.

Karan JollyKeshav Kumar GuptaAbishek BanotaShahzada K Ahmed
Published in: American journal of rhinology & allergy (2021)
Many studies have demonstrated IF to be safe at low doses (<50mg) with a high sensitivity, specificity and positive predicative value. Our results demonstrate that the use of IF in our centre is safe and effective at identifying CSF fistulae. While we have reported some complications in our cohort, these were unlikely to be directly attributable IF use. We have described no serious complications such as seizures, limb weakness or death. We believe this study adds to the growing body of evidence that IF use in the management CSF fistula repairs is safe and effective.
Keyphrases
  • cerebrospinal fluid
  • risk factors