Login / Signup

Reliability of mixed dentition space analysis using a digital model obtained from an optical impression: a preliminary study.

Ayuko OkamotoHiroyuki KaribeSatoshi TanakaTomomi KawakamiAkikazu Shinya
Published in: BMC research notes (2024)
The space required for the mandibular permanent canine and premolars and arch length discrepancy were calculated using each model. The largest significant difference between plaster- and digital model-based analyses was identified when the right arch length discrepancy was considered (-0.49 mm; 95% confidence interval: -0.95-0.03); however, the value was considered clinically insignificant. Significant inter-examiner differences were observed for six items of the plaster model; however, no such differences were observed when using the digital model. In conclusion, digital model space analysis may have the same level of accuracy as conventional plaster model analysis and likely results in smaller inter-examiner differences than plaster model analysis.
Keyphrases
  • mass spectrometry
  • high speed