Regional lung function measures determined by electrical impedance tomography during repetitive ventilation manoeuvres in patients with COPD.

L LasarowB VogtZhanqi ZhaoL BalkeN WeilerInéz Frerichs
Published in: Physiological measurement (2021)
Measures of spatial and temporal ventilation heterogeneity obtained in COPD patients by EIT provide comparable findings during repeated examinations within one testing session. Quiet tidal breathing generates similar information on ventilation heterogeneity as forced manoeuvres that demand a high amount of patient effort.