Comparison of QCT and DEXA findings for lumbar vertebra in young adults and the elderly.
Güneş AçikgözAydın BoraSüreyya NurPublished in: Acta radiologica (Stockholm, Sweden : 1987) (2024)
In the study, it was observed that QCT attenuation measurements of the lumbar spine measured between different age groups provided reliable results in terms of BMD scanning, as in DEXA. It should be noted that QCT has a longer imaging time and higher radiation dose compared to DEXA, and unnecessary scans should be avoided.