Login / Signup

Evaluation of an Artificial Neural Network Retention Index Model for Chemical Structure Identification in Nontargeted Metabolomics.

Milinda A SamaraweeraL Mark HallDennis W HillDavid F Grant
Published in: Analytical chemistry (2018)
Liquid chromatography coupled with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is a major analytical technique used for nontargeted identification of metabolites in biological fluids. Typically, in LC-ESI-MS/MS based database assisted structure elucidation pipelines, the exact mass of an unknown compound is used to mine a chemical structure database to acquire an initial set of possible candidates. Subsequent matching of the collision induced dissociation (CID) spectrum of the unknown to the CID spectra of candidate structures facilitates identification. However, this approach often fails because of the large numbers of potential candidates (i.e., false positives) for which CID spectra are not available. To overcome this problem, CID fragmentation predication programs have been developed, but these also have limited success if large numbers of isomers with similar CID spectra are present in the candidate set. In this study, we investigated the use of a retention index (RI) predictive model as an orthogonal method to help improve identification rates. The model was used to eliminate candidate structures whose predicted RI values differed significantly from the experimentally determined RI value of the unknown compound. We tested this approach using a set of ninety-one endogenous metabolites and four in silico CID fragmentation algorithms: CFM-ID, CSI:FingerID, Mass Frontier, and MetFrag. Candidate sets obtained from PubChem and the Human Metabolite Database (HMDB) were ranked with and without RI filtering followed by in silico spectral matching. Upon RI filtering, 12 of the ninety-one metabolites were eliminated from their respective candidate sets, i.e., were scored incorrectly as negatives. For the remaining seventy-nine compounds, we show that RI filtering eliminated an average of 58% from PubChem candidate sets. This resulted in an approximately 2-fold improvement in average rankings when using CFM-ID, Mass Frontier, and MetFrag. In addition, RI filtering slightly increased the occurrence of number one rankings for all 4 fragmentation algorithms. However, RI filtering did not significantly improve average rankings when HMDB was used as the candidate database, nor did it significantly improve average rankings when using CSI:FingerID. Overall, we show that the current RI model incorrectly eliminated more true positives (12) than were expected (4-5) on the basis of the filtering method. However, it slightly improved the number of correct first place rankings and improved overall average rankings when using CFM-ID, Mass Frontier, and MetFrag.
Keyphrases