Automated estimation of ischemic core prior to thrombectomy: comparison of two current algorithms.
Lakshini GunasekeraLeonid ChurilovPeter MitchellAndrew BivardGagan SharmaMark W ParsonsBernard YanPublished in: Neuroradiology (2021)
The ddSVD algorithm better correlates with DWI follow-up infarct volume than DISD processing. The DISD algorithm overestimated larger ischemic cores which may lead to patient exclusion from thrombectomy based on selection by core volume.