Login / Signup

An Adaptive and Time-Efficient ECG R-Peak Detection Algorithm.

Qin QinJianqing LiYinggao YueChengyu Liu
Published in: Journal of healthcare engineering (2017)
R-peak detection is crucial in electrocardiogram (ECG) signal analysis. This study proposed an adaptive and time-efficient R-peak detection algorithm for ECG processing. First, wavelet multiresolution analysis was applied to enhance the ECG signal representation. Then, ECG was mirrored to convert large negative R-peaks to positive ones. After that, local maximums were calculated by the first-order forward differential approach and were truncated by the amplitude and time interval thresholds to locate the R-peaks. The algorithm performances, including detection accuracy and time consumption, were tested on the MIT-BIH arrhythmia database and the QT database. Experimental results showed that the proposed algorithm achieved mean sensitivity of 99.39%, positive predictivity of 99.49%, and accuracy of 98.89% on the MIT-BIH arrhythmia database and 99.83%, 99.90%, and 99.73%, respectively, on the QT database. By processing one ECG record, the mean time consumptions were 0.872 s and 0.763 s for the MIT-BIH arrhythmia database and QT database, respectively, yielding 30.6% and 32.9% of time reduction compared to the traditional Pan-Tompkins method.
Keyphrases
  • heart rate variability
  • heart rate
  • machine learning
  • adverse drug
  • loop mediated isothermal amplification
  • deep learning
  • label free
  • neural network
  • drug induced
  • blood pressure
  • electronic health record