Diamond-like carbon (DLC) surface treatment decreases biofilm burden by S. aureus on titanium alloy in vitro- a pilot study.
Anabelle VisperasKaixi CuiMd Masud AlamShonali SubramanianEvan ButschAlison K KlikaAnna Cristina SamiaNicolas Santiago PiuzziPublished in: European journal of orthopaedic surgery & traumatology : orthopedie traumatologie (2024)
DLC-coated titanium alloy implants may have preventative properties in S. aureus infection. Observing differences in biofilm coverage does warrant additional testing including CFU titration and biofilm kinetics with eventual use in an animal model of periprosthetic joint infection.