). PLM-induced hyperemia yielded within-day coefficients of variation (CV) from 10.9 to 22.9%, intraclass correlation coefficients (ICC) from 0.82 to 0.90, standard error of the measurement (SEM) from 8.3 to 17.2%, and Pearson's correlation coefficients (r) from 0.56 to 0.81. Between-day assessments of PLM hyperemia resulted in CV from 14.4 to 25%, ICC from 0.75 to 0.87, SEM from 9.8 to 19.8%, and r from 0.46 to 0.75. Similar to previous reports in women, the hyperemic responses to PLM in men display moderate-to-high reliability, and are comparable to reliability data for brachial artery flow mediated vasodilation. These positive reliability findings further support the utility of PLM as a clinical measurement of vascular function and cardiovascular disease risk.