Simulation of thoracic endovascular aortic repair in a perfused patient-specific model of type B aortic dissection.
Lukas MohlRoger KarlMatthias Niklas HagedornArmin RunzStephan SkornitzkeMalte ToelleC Soeren BergtJohannes HatzlChristian UhlDittmar BöcklerKatrin MeisenbacherSandy EngelhardtPublished in: International journal of computer assisted radiology and surgery (2024)
This perfused in-vitro phantom allows for detailed investigation of the complex inner hemodynamics of aortic dissections on a patient-specific level and enables the simulation of TEVAR procedures in a real endovascular operating environment. Therefore, it could provide a dynamic platform for future surgical training and research.