Long-term outcome and chronic pain in atraumatic fibrin glue versus staple fixation of extra light titanized meshes in laparoscopic inguinal hernia repair (TAPP): a single-center experience.

Ulrich WirthMarie Luise SallerThomas von AhnenFerdinand KöckerlingHans Martin SchardeyStefan Schopf
Published in: Surgical endoscopy (2019)
Inguinal hernia repair using extra lightweight titanized meshes and fibrin glue fixation is safe and feasible compared to staple fixation even in large and combined hernia defects, if mesh size is adjusted to size of hernia defect. The rate of chronic pain was extremely low at 2.4%.