HER2 fluorescent in situ hybridization signal degradation: a 10-year retrospective study.
Jessie M WuAndrey-Ann GaliboisNeha SeebocusAnupam ApuMarta HnatovskaAnnie WilsonTeresa ShortillGulisa TurashviliPublished in: Breast cancer research and treatment (2021)
Our study is the first to demonstrate HER2 FISH signal degradation with time and slide storage conditions. Storing HER2 FISH slides in a -80 °C freezer allows for retention of both HER2 and CEP17 signals. At room temperature, the signals start to degrade with CEP17 signals lost at a faster rate. The results of the study may be used in official guidelines for storage conditions and retention time for HER2 FISH slides.