Login / Signup

Microdebrider is less aerosol-generating than CO2 laser and cold instruments in microlaryngoscopy.

Enni SanmarkLotta-Maria A H OksanenNoora RantanenMari LahelmaVeli-Jukka AnttilaNina AtanasovaAntti-Pekka HyvärinenTeemu KinnariAhmed Geneid
Published in: European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery (2021)
Microdebrider and cold dissection can be regarded as aerosol-generating relative to background reference concentrations, but they should not be considered as high-risk aerosol-generating procedures, as the concentrations are low and do not exceed those of coughing. A step-down algorithm from CO2 laser to cold instruments and microdebrider is recommended to lower the risk of airborne infections among medical staff.
Keyphrases
  • water soluble
  • healthcare
  • machine learning
  • particulate matter
  • high speed
  • mass spectrometry
  • high resolution
  • air pollution