Biomechanical Performance of Mandibular Molars with Deep Mesio-Occlusal-Distal Cavities Rehabilitated with Horizontal Posts: A 3D Finite Element Analysis.
Sonali SharmaSindhu RameshJasmine RayapudiPublished in: International journal of dentistry (2023)
Rehabilitation of deep mesio-occlusal-distal cavities of molars with intact buccal and lingual walls with the aid of a horizontal post of any diameter has a similar stress distribution to an intact tooth. However, the biomechanical performance of a 2 mm horizontal post was exacting of the natural tooth. Horizontal posts can be included in expanding our restorative option for rehabilitating grossly mutilated teeth.