Hydrofluorocarbons pneumonitis as a complication of inhalation injury following air-conditioning repairs.

Afifah Aqilah Abdul MalikBoon Hau NgNik Nuratiqah Nik AbeedMohamed Faisal Abdul HamidAndrea Yu-Lin Ban
Published in: Respirology case reports (2022)
Hydrofluorocarbon (HFC) pneumonitis is an uncommon cause of inhalation injury. HFCs are a group of chemicals predominantly used for refrigeration and cooling. A 19-year-old air-conditioning technician developed acute onset of dyspnoea and chest tightness while servicing an air conditioner in a confined space. We diagnosed him with HFC pneumonitis based on the history of exposure and the high-resolution computed tomography (HRCT) thorax findings. He was treated with steroids and supportive oxygen therapy. He recovered fully after 5 days of hospitalization and was discharged. Review at 2 weeks in the outpatient setting showed significant radiological improvement on HRCT thorax.