Capturing infant swallow impairment on videofluoroscopy: timing matters.
Katlyn Elizabeth McGrattanHeather C McGheeKeeley L McKelveyClarice S ClemmensElizabeth G HillAllan DeTomaJeanne G HillCephus E SimmonsBonnie Martin-HarrisPublished in: Pediatric radiology (2019)
Fluoroscopic visualization that is confined to the initial swallows of the bottle feed limit the exam's diagnostic validity. Developing evidence-based procedural guidelines for infant VFSS execution is crucial for maximizing the exam's diagnostic and treatment yield.