Three-year clinical outcome of XEN45 Gel Stent implantation versus trabeculectomy in patients with open angle glaucoma.
Teresa RaucheggerSarah-Maria KrauseYvonne NowosielskiAnna Lena HuberPeter WilleitEduard SchmidBarbara TeuchnerPublished in: Eye (London, England) (2024)
Compared to XEN, TRAB was associated with lower intraocular pressure, less IOP-lowering medication, and higher probability of achieving complete surgical success over a 36-month follow-up period.