Login / Signup

Performance and outcome of the subcutaneous implantable cardioverter-defibrillator after transvenous lead extraction.

Da-Un ChungJohannes TauberLukas KaiserAndrea SchlichtingSimon PechaChristoph R SinningEnida RexhaHermann ReichenspurnerStephan WillemsNils GosauSamer Hakmi
Published in: Pacing and clinical electrophysiology : PACE (2021)
The S-ICD is a safe and effective alternative for patients after TLE with very similar results regarding device performance and postoperative outcome, when compared to patients who underwent de-novo S-ICD implantation.
Keyphrases
  • end stage renal disease
  • chronic kidney disease
  • newly diagnosed
  • ejection fraction
  • peritoneal dialysis