Normothermic Ex Situ Machine Perfusion of Vascularized Composite Allografts with Oxygen Microcarriers for 12 Hours Using Real-Time Mitochondrial Redox Quantification.
Valentin HaugYifeng PengBianief TchiloembaAlice T WangFlorian BuergerPadraic RomfhUlrich KneserBrian D PolizzottiBohdan PomahacPublished in: Journal of clinical medicine (2023)
The use of oxygen microcarriers in ex situ perfusion of VCA with acellular perfusates under normothermic conditions for 12 h facilitates the maintenance of mitochondrial structure, as well as a subsequent recovery of mitochondrial redox status over time, while markers of muscle injury were lower compared to conventional oxygenated acellular perfusates.