Diaphragm reconstruction using a TachoSil patch as alternative to intrasellar packing for small focal diaphragm defects in pituitary surgery: a cohort study.
Bertrand BaussartBenoit HudelistVincent ReinaChiara VillaJérôme BertheratGuillaume AssiéStephan GaillardPublished in: Acta neurochirurgica (2024)
In highly selected patients with low-flow CSF leaks related to small focal diaphragm defects, diaphragm reconstruction using a TachoSil patch can be a safe and valuable alternative to intrasellar packing.