Login / Signup

Does Intolerance of Single-Lung Ventilation Preclude Robotic Off-Pump Totally Endoscopic Coronary Bypass Surgery?

Husam H BalkhySarah M NisivacoAvery TungGianluca TorregrossaSachin Mehta
Published in: Innovations (Philadelphia, Pa.) (2020)
In our cohort, intolerance of single-lung ventilation did not preclude robotic off-pump TECAB. Double-lung ventilation is feasible during the procedure and may prevent conversions to sternotomy or use of CPB, resulting in excellent early and mid-term outcomes.