Patients' openness to discussing implantable cardioverter defibrillator deactivation at end of life: a cross-sectional study.
Kyoung Suk LeeOonjee OhJennifer MillerMuna HammashDavid R ThompsonChantal F SkiJanette CameronSeon Young HwangDebra K MoserPublished in: European journal of cardiovascular nursing (2022)
Approximately half of the ICD recipients were reluctant to discuss device deactivation at end of life with clinicians. Unmodifiable factors were their living arrangement and severe comorbidity. ICD knowledge and prior experience discussing end-of-life issues were potentially modifiable factors in the future. These factors should be addressed when assessing patients' readiness for a shared discussion about device deactivation at end of life.