Adapting the vertical position of implants with a conical connection in relation to soft tissue thickness prevents early implant surface exposure: A 2-year prospective intra-subject comparison.
Stijn VervaekeCarine MatthysRima NassarVeronique ChristiaensJan CosynHugo De BruynPublished in: Journal of clinical periodontology (2018)
Initial bone remodelling was affected by soft tissue thickness. Anticipating biologic width re-establishment by adapting the vertical position of the implant seemed highly successful to avoid implant surface exposure.