Use of computerized campimetry and/or optical coherence tomography for glaucoma diagnosis by non-glaucoma specialists.
Cláudia Gomide Vilela de Sousa FrancoMarcos Pereira de ÁvilaMarcos P ÁvilaPublished in: Arquivos brasileiros de oftalmologia (2021)
Non-glaucoma specialists could not differentiate glaucoma from increased physiological cupping when using color retinography assessment alone. Diagnostic accuracy and inter-rater agreement improved significantly with the addition of visual field or optical coherence tomography. However, the use of both modalities did not improve sensitivity/specificity.