Transcutaneous bone conductive implants in patients with conductive/mixed hearing loss: audiological outcomes in noise condition.

Giuseppe MagliuloGiannicola IannellaMarco De VincentiisRosaria TurchettaGinevra PortanovaDiletta AngelettiPatrizia Mancini
Published in: Acta oto-laryngologica (2018)
Sophono Alpha System devices represent a valid treatment option for hearing rehabilitation of patients with conductive or mixed hearing loss. The audiological results regarding hearing gain in noise conditions were good.