Login / Signup

Factors associated with pessary fitting in women with symptomatic pelvic organ prolapse: A large prospective cohort study.

Congcong MaTao XuJia KangYe ZhangYidi MaShuo LiangLan Zhu
Published in: Neurourology and urodynamics (2020)
Stage IV prolapse, posterior compartment prolapse, large genital hiatus, and wide vaginal introitus were risk factors for unsuccessful fitting of ring pessary with support. Short vaginal length and a history of POP reconstructive surgery were risk factors for unsuccessful fitting of both pessaries.
Keyphrases
  • preterm birth
  • minimally invasive
  • coronary artery bypass
  • urinary incontinence
  • atrial fibrillation