Comparison of the ability of Reciproc and Reciproc Blue instruments to reach the full working length with or without glide path preparation.

Mehmet AdıgüzelPelin Tufenkci
Published in: Restorative dentistry & endodontics (2018)
Preparation of a glide path did not have a significant effect on reaching the full working length using these systems.