Feasibility Study of Synthetic Diffusion-Weighted MRI in Patients with Breast Cancer in Comparison with Conventional Diffusion-Weighted MRI.
Bo Hwa ChoiHye Jin BaekJi Young HaKyeong Hwa RyuJin Il MoonSung-Eun ParkKyungsoo BaeKyung Nyeo JeonEun Jung JungPublished in: Korean journal of radiology (2020)
sDWI1500 can be feasible for evaluating breast cancers in clinical practice. It provides higher tumor conspicuity, better cancer-to-parenchyma contrast ratio, and comparable CDR when compared with cDWI1500.