Effect of Interlocking Mode on the Outcomes of Exchange Nailing for the Treatment of Aseptic Femoral Shaft Nonunion.

Kyu-Hyun YangChan-Hee LeeYoung-Chang Park
Published in: Clinics in orthopedic surgery (2023)
Exchange nailing with dynamic mode yields a higher success rate and shorter time to union in aseptic femoral shaft nonunion than that with static mode, without the risk of excessive shortening.