Comparison of glue versus suture mesh fixation for primary open inguinal hernia mesh repair by Lichtenstein technique: a systematic review and meta-analysis.
Shaun PhoaKai Siang ChanSioh Huang LimAung Myint OoVishal G ShelatPublished in: Hernia : the journal of hernias and abdominal wall surgery (2022)
Early and late recurrence were comparable between glue and suture fixation in open Lichtenstein IHR patients. Glue fixation had shorter operating time and lower haematoma formation than suture fixation. Chronic pain and seroma formation were comparable. More RCTs should report long-term outcomes.