Tensile strength assay comparing the resistance between two different autologous platelet concentrates (leucocyte-platelet rich fibrin versus advanced-platelet rich fibrin): a pilot study.

Martim de Almeida Nóbrega Correia PascoalNuno Bernardo Malta Dos SantosAntónio Manuel Godinho CompletoGustavo Vicentis de Oliveira Fernandes
Published in: International journal of implant dentistry (2021)
With this study, it was possible to conclude that indeed A-PRF has a significative higher maximal traction score and higher average traction compared to L-PRF, indicating that it had a higher resistance when two opposing forces are applied.