Comparative diagnostic performance of ultrasound shear wave elastography and magnetic resonance elastography for classifying fibrosis stage in adults with biopsy-proven nonalcoholic fatty liver disease.

Yingzhen N ZhangKathryn J FowlerAndrew S BoehringerVivian MontesAlexandra N SchleinYesenia CovarrubiasTanya WolfsonCheng W HongMark A ValasekMichael P AndreRohit LoombaClaude B Sirlin
Published in: European radiology (2021)
• For detecting any fibrosis or mild fibrosis, MR elastography was significantly more accurate than shear wave elastography. • For detecting advanced fibrosis and cirrhosis, MRE and SWE did not differ significantly in accuracy. • For excluding advanced fibrosis and potentially ruling out the need for biopsy, SWE and MRE did not differ significantly in negative predictive value. • Neither SWE nor MRE had sufficiently high positive predictive value to rule in advanced fibrosis.
Keyphrases
  • liver fibrosis
  • magnetic resonance
  • magnetic resonance imaging
  • high resolution
  • computed tomography