Structural Characterization of Sulfated Glycosaminoglycans Using Charge-Transfer Dissociation.
Lauren E PepiZachary J SasienePraneeth M MendisGlen P JacksonI Jonathan AmsterPublished in: Journal of the American Society for Mass Spectrometry (2020)
Glycosaminoglycans (GAGs) participate in a broad range of physiological processes, and their structures are of interest to researchers in structural biology and medicine. Although they are abundant in tissues and extracellular matrices, their structural heterogeneity makes them challenging analytes. Mass spectrometry, and more specifically, tandem mass spectrometry, is particularly well suited for their analysis. Many tandem mass spectrometry techniques have been examined for their suitability toward the structural characterization of GAGs. Threshold activation methods such as collision-induced dissociation (CID) produce mainly glycosidic cleavages and do not yield a broad range of structurally informative cross-ring fragments. Considerable research efforts have been directed at finding other means of dissociating gas-phase GAG ions to produce more comprehensive structural information. Here, we compare the structural information on GAGs obtained by charge-transfer dissociation (CTD) and electron detachment dissociation (EDD). EDD has previously been applied to GAGs and is known to produce both glycosidic and cross-ring cleavages in similar abundance. CTD has not previously been used to analyze GAGs but has been shown to produce abundant cross-ring cleavages and no sulfate loss when applied to another class of sulfated carbohydrates like algal polysaccharides. In contrast to EDD, which is restricted to FTICR mass spectrometers, CTD can be implemented on other platforms, such as ion trap mass spectrometers (ITMS). Here, we show the capability of CTD-ITMS to produce structurally significant details of the sites of modification in both heparan sulfate (HS) and chondroitin sulfate (CS) standards ranging in length from degree of polymerization (dp) 4 to dp6. EDD and CTD both yield more structural information than CID and yield similar fractional abundances to one another for glycosidic fragments, cross-ring fragments, and neutral losses.
Keyphrases
- tandem mass spectrometry
- liquid chromatography
- high performance liquid chromatography
- ultra high performance liquid chromatography
- gas chromatography
- mass spectrometry
- simultaneous determination
- high resolution
- electron transfer
- solid phase extraction
- high resolution mass spectrometry
- health information
- magnetic resonance
- high glucose
- healthcare
- drug induced
- oxidative stress
- wastewater treatment
- ms ms
- capillary electrophoresis