Monitoring exercise intensity in diabetes: applicability of "heart rate-index" to estimate oxygen consumption during aerobic and resistance training.
Alessandro L ColosioG SpigolonE BacchiPaolo MoghettiSilvia PogliaghiPublished in: Journal of endocrinological investigation (2019)
VO2 of aerobic exercises can be accurately estimated in diabetes patients using HRindex. During isotonic exercise, this method is not recommended for monitoring metabolic intensity due to large overestimation and imprecision. In aerobic exercise, HRindex offers a simple and valid alternative to the direct VO2 determination and may favour the applicability of time-resolved measures of exercise "dose".
Keyphrases
- high intensity
- resistance training
- heart rate
- type diabetes
- end stage renal disease
- heart rate variability
- cardiovascular disease
- body composition
- blood pressure
- glycemic control
- ejection fraction
- chronic kidney disease
- newly diagnosed
- peritoneal dialysis
- patient reported outcomes
- metabolic syndrome
- high resolution
- insulin resistance