Comparative differences in the latencies of cVEMP responses between and within stimuli could be due to the variation in stimuli duration. Also, the difference in amplitudes across stimulation frequencies might have resulted due to the predominance of saccular responses at lower mechanical resonance frequencies. Thus, the tuning was also seen at 500 Hz and was relatively higher for NB CE-chirps than tone bursts.