Login / Signup

Comparison of Patellofemoral Outcomes between Attune and PFC Sigma Designs: A Prospective Matched-Pair Analysis.

Rajesh Navin ManiarNishit BhatnagarRohan BidwaiAnkur DhimanDebashish ChandaNishant Sanghavi
Published in: Clinics in orthopedic surgery (2021)
We observed that both Attune and PFC Sigma had a low and comparable incidence of AKP and PCr up to 2 years of follow-up. The Attune group achieved a significantly greater ROM at 3 months postoperatively. At 2 years of follow-up, both prostheses had excellent and comparable clinical and functional results.
Keyphrases
  • total knee arthroplasty
  • type diabetes
  • metabolic syndrome