Efficiency of cold atmospheric plasma, cleaning powders and their combination for biofilm removal on two different titanium implant surfaces.
Julia KamionkaRutger MatthesBirte HoltfreterChristiane PinkRabea SchlüterThomas von WoedtkeThomas KocherLukasz JablonowskiPublished in: Clinical oral investigations (2022)
Microbial residuals impede wound healing and re-osseointegration after peri-implantitis treatment. Air-polishing treatment removes biofilms very effectively, but not completely. In combination with CAP, microbial free surfaces can be achieved. The tested treatment regime offers an advantage during treatment of peri-implantitis.