Management of XEN Gel Stent Exposure with Conjunctival Erosion via Rotational Conjunctival Flap and Amniotic Membrane Transplantation-A Case Report.
Chang Kyu LeeJe-Hyun SeoSu-Ho LimPublished in: Medicina (Kaunas, Lithuania) (2022)
Background : Despite its proven effectiveness and safety profile, the XEN gel stent (Allergan Inc., CA, USA) for minimally invasive glaucoma surgery (MIGS) has a probability of postoperative complications, including postoperative hypotony, hyphema, stent migration, stent obstruction, bleb fibrosis, and fibrin formation. In particular, the use of adjunctive Mitomycin-C (MMC) might be associated with bleb-related complications, including conjunctival erosion, XEN gel stent exposure, and blebitis. However, there are few studies on XEN gel stent exposure and its management. We describe a case of XEN gel stent exposure with conjunctival erosion 18 months postoperatively, which resolved effectively after combination treatment with a rotational conjunctival flap and amniotic membrane transplantation. Case presentation : A 74-year-old Korean male patient with diabetes and hypertension underwent uncomplicated ab interno XEN gel stent implantation with a subconjunctival injection of 0.1 cc of 0.02% MMC and presented with low intraocular pressure (IOP) with a well-functioning filtering bleb. Periocular pain and tearing developed 18 months after the initial operation, with mild deterioration of visual acuity to 20/100. Despite conservative medical treatment, the conjunctival erosion was not relieved. Anterior segment optical coherence tomography (AS-OCT) revealed an exposed XEN gel stent with conjunctival erosion. We performed bleb revision surgery using a rotational conjunctival flap and amniotic membrane transplantation. Slit-lamp examination and AS-OCT showed a well-formed moderate bleb without leakage, and IOP continued to be well controlled (14 mm Hg with latanoprost) until six months after bleb revision. Conclusions : This case report highlights the importance of careful examination, including slit-lamp examination, the Seidel test, and AS-OCT, to identify accurate anatomical positioning and to monitor ocular surface changes after XEN gel stent implantation with MMC or 5-FU. Combination treatment (rotational conjunctival flap and amniotic membrane transplantation) may be relatively safe for persistent XEN gel stent exposure.
Keyphrases
- minimally invasive
- optical coherence tomography
- case report
- wound healing
- healthcare
- blood pressure
- cardiovascular disease
- stem cells
- metabolic syndrome
- cell therapy
- mass spectrometry
- coronary artery disease
- bone marrow
- single cell
- acute coronary syndrome
- diabetic retinopathy
- total hip arthroplasty
- neuropathic pain
- pain management
- combination therapy
- spinal cord
- loop mediated isothermal amplification