Login / Signup

A 7.5-year randomized controlled clinical study comparing cemented and screw-retained one-piece zirconia-based implant-supported single crowns.

Riccardo D KrausJenni HjerppeNadja NaenniMarc BalmerRonald Ernst JungDaniel Stefan Thoma
Published in: Clinical oral implants research (2024)
One-piece zirconia-based single crowns on two-piece dental implants exhibited a high rate of technical and biological complications at 7.5 years of follow-up. Cemented restorations revealed significant higher rates of bleeding on probing and total complications compared to screw-retained restorations.
Keyphrases