Lung thermography during the initial reperfusion period to assess pulmonary function in cellular ex vivo lung perfusion.
Ryo KosakaDaisuke SakotaHiromichi NiikawaKatsuhiro OhuchiHirokuni AraiKenneth R McCurryToshihiro OkamotoPublished in: Artificial organs (2022)
A lung surface temperature of ≥26°C at 8 min is a good early predictor of transplant suitability in cellular EVLP and might be applicable in clinical EVLP.