Changes in corneal endothelial cell density after initial Ex-PRESS drainage device implantation and its relating factors over 3 years.
Yurika AoyamaRei SakataTakashi FujishiroMegumi HonjoShiroaki ShiratoMakoto AiharaPublished in: Eye (London, England) (2022)
CECD after initial Ex-PRESS surgery in 36 months might not be clinically problematic. However, longer-term follow-up is necessary, and regular CECD measurement should be performed, especially in patients with low CECD.